Please wait...
The product was added to the shopping cart. View shopping cart
Cart is empty

EIZO MATCHED FOR MAMMODUO SOLUTION (ALWAYS ORDER PAIRWISE) DOWN

Frontpage Monitor/TV Monitor EIZO MATCHED FOR MAMMODUO SOLUTION (ALWAYS ORDER PAIRWISE) DOWN
You have to log in to shop/see prices.
EIZO MATCHED FOR MAMMODUO SOLUTION (ALWAYS ORDER PAIRWISE) DOWN (RX560-MD)
EIZO MATCHED FOR MAMMODUO SOLUTION (ALWAYS ORDER PAIRWISE) DOWN (RX560-MD)
EIZO MATCHED FOR MAMMODUO SOLUTION (ALWAYS ORDER PAIRWISE) DOWN (RX560-MD)
EIZO MATCHED FOR MAMMODUO SOLUTION (ALWAYS ORDER PAIRWISE) DOWN (RX560-MD)
EIZO MATCHED FOR MAMMODUO SOLUTION (ALWAYS ORDER PAIRWISE) DOWN (RX560-MD)
EIZO MATCHED FOR MAMMODUO SOLUTION (ALWAYS ORDER PAIRWISE) DOWN (RX560-MD)
EIZO MATCHED FOR MAMMODUO SOLUTION (ALWAYS ORDER PAIRWISE) DOWN (RX560-MD)
EIZO MATCHED FOR MAMMODUO SOLUTION (ALWAYS ORDER PAIRWISE) DOWN (RX560-MD)
EIZO MATCHED FOR MAMMODUO SOLUTION (ALWAYS ORDER PAIRWISE) DOWN (RX560-MD)
EIZO MATCHED FOR MAMMODUO SOLUTION (ALWAYS ORDER PAIRWISE) DOWN (RX560-MD)
EIZO MATCHED FOR MAMMODUO SOLUTION (ALWAYS ORDER PAIRWISE) DOWN (RX560-MD)
EIZO MATCHED FOR MAMMODUO SOLUTION (ALWAYS ORDER PAIRWISE) DOWN (RX560-MD)

EIZO MATCHED FOR MAMMODUO SOLUTION (ALWAYS ORDER PAIRWISE) DOWN

SKU:
RX560-MD
  • Size 21.3"
  • HD QSXGA
  • DVI 1
  • DP 2
  • HDMI 0
  • VGA 0
  • Touchscreen No
  • Speakers No
  • 3D No
  • Screen Shape Flat
  • Height adjustment Yes
  • Swivelling Yes
  • Pivot No
  • Usage Personal display
Out of stock
Description

RadiForce RX560


This 5 megapixel, high-brightness color monitor has the high-definition display necessary for breast imaging. It combines ease-of-use, such as a narrow bezel design to help your eyes swiftly move from one monitor to another, with new functions to help you focus on your work and maintain high performance.

The RX560 MammoDuo integrates two RX560 monitors side by side on a specifically designed stand.

Distraction-Free Viewing
The monitor bezel is just 7.5 mm – the world's narrowest bezel on a 5 megapixel monitor; making the total distance between the visible screens of the two monitors only 15 mm. Furthermore, the bezel sits only 2.5 mm above the screen, making an almost completely flush bezel to easily switch your view between screens.

Space Saving
The dimensions of the RX560 MammoDuo are reduced by 67 mm horizontally, 36 mm vertically, and 20.5 mm in depth compared to a conventional side-by-side configuration with a single monitor of the same total resolution. The total space occupied by the monitors was reduced by 22%, creating a more unrestricted environment with expanded viewing space.

Easy Adjustment
With the newly designed stand, you can adjust the height, tilt, and swivel of the two monitors without any gaps appearing between them.

Clean and Sophisticated
The black front bezels are ideal for viewing the screen in dark reading rooms, making it easier to focus on images, while the original white stripe around the sides of the monitor presents a fresh, clean aesthetic.

Evolve Your Image Reading
As more image modalities become digitalized, radiologists are viewing an increasing amount of information on their screens. EIZO's unique Work-and-Flow technology alleviates the complexity of the imaging workflow with new functions developed with the radiologist in mind. Users can take advantage of Work-and-Flow features with the RadiForce monitor and bundled RadiCS LE software.

Quick and Easy Focus
With the Point-and-Focus function, you can quickly select and focus areas of your concern with just your mouse and keyboard. Change the brightness and grayscale tones of certain points on the screen to make interpretation easier.

Full Color Support for Ultrasound, Breast CT and MRI
Breast cancer screenings are increasingly combining the use of mammography and ultrasound to view patients with high breast density. Furthermore, if breast cancer is suspected, various other tests may also be needed such as biopsy, breast MRI and CT.
The RX560 is the world's first medical monitor to use low temperature polysilicon (LTPS) liquid crystal display. Because of this, the color monitor can reach a brightness of up to 1100 cd/m2, similar to that of monochrome monitors. Due to this high brightness, the RX560 can display high-definition monochrome breast tomosynthesis and mammography images with deep blacks and no washout in addition to color images such as ultrasound and pathology.
Furthermore it has a high contrast ratio of 1500:1, approximating that of a monochrome monitor, displaying deep blacks without any washout.

Optimum Breast Screening Monitor
The monitor has obtained FDA 510(k) clearance by the U.S. Food and Drug Administration for breast tomosynthesis and mammography. This ensures that the monitor is capable of displaying detailed breast screening images where high performance is essential.

Display Both Monochrome and Color
Hybrid Gamma PXLThe Hybrid Gamma PXL function automatically distinguishes between monochrome and color images pixel by pixel, creating a hybrid display where each pixel has optimum grayscale; giving it greater accuracy and reliability than the conventional area-detection method.
In addition to breast tomosynthesis and mammography monochrome images, which require high display performance, the RX560 also faithfully reproduces color images such as breast MRI and CT, ultrasound, and pathology. This ultimately improves efficiency by allowing both monochrome and color images to be viewed on one screen.

EIZO, in collaboration with the Federation of National Public Service Personnel Mutual Aid Association of Kumamoto Chuo Hospital, Japan, conducted a visual assessment of the function. As a result of comparing monitors with the function turned on and off, it was found that Hybrid Gamma PXL accurately displays monochrome images according to DICOM Part 14, and actually improved accuracy of color image interpretation.

Smooth Display of Breast Tomosynthesis
The monitor has a response time of 12 milliseconds, making it ideal for enlarging and panning medical images, as well as quickly displaying 3D breast tomosynthesis which comprises of several images in each shot.

Hassle-Free Multi-Monitor Configuration
The monitor is equipped with DisplayPort 1.2 input and output terminals. Using the output terminal allows you to easily configure several monitors in a daisy chain sequence without the hassle of excessive cabling.

Variations for Specific User Needs
EIZO offers anti-glare (AG) and anti-reflection (AR) screen variations to suit user environments. AG treatment is ideal for exceptionally bright environments and drastically reduces glare from ambient lighting. AR treatment is ideal for moderately-lit environments to reduce mild screen glare while maintaining crisp text and images.

Achieve Clarity True to the Source Data
A medical monitor needs to be capable of high brightness in order to meet performance standards. However, in order to achieve high brightness in an LCD panel, the pixel aperture ratio has to be increased. This causes a typically unavoidable decline in sharpness. With EIZO's unique Sharpness Recovery technology, the decrease in sharpness (MTF) is restored . This allows you to display an image safely on the monitor that is true to the original source data, even at high brightness levels.
MTF measures numerically how faithfully the panel transfers detail from the original image data for viewing. When Sharpness Recovery is turned on, in the case of a 2 pixel line pair (spatial frequency of 1.515 cycles/mm) the MTF increases by approximately 45%.

Clear, High Density Images
The monitor hosts 0.165 mm pixels, realizing a smooth, high-density, high-definition image without graininess.

Make the Precise Diagnosis
EIZO carefully measures and sets each grayscale tone to create a monitor compliant with DICOM Part 14. This ensures the most consistent shading possible, allowing for the most accurate diagnosis.

Simple Calibration with Built-In Sensor
The monitor hosts an Integrated Front Sensor (IFS). It is built into the bezel and is only visible when in use; not needing any time to set up. By using it together with the included monitor control software RadiCS LE, brightness and gradation can be corrected to match DICOM Part 14 standards.

Experience Smooth Color Reproduction
The monitor supports 10-bit input for each RGB color, displaying more than one billion colors simultaneously. This ensures accurate color reproduction for images such as MRI, ultrasound, and pathology.

Comfortable View from Any Angle
Wide viewing angles allow you to view the screen from the side with minimal color shift, also permitting more than one person to view the monitor comfortably at the same time.

View Accurate Images in Moments
The EIZO-patented drift correction function quickly stabilizes the brightness level of the monitor upon startup or wakeup from sleep mode, giving you the most accurate images quickly ready for viewing. In addition, a sensor measures the backlight brightness and automatically compensates for brightness fluctuations caused by ambient temperature and aging for a consistently stable display.

Attain Steady Images Across the Screen
The Digital Uniformity Equalizer (DUE) function helps to even out fluctuations in brightness and chroma on different parts of the screen to provide smoother images.

Select the Ideal Mode for Modalities
The CAL Switch function allows you to choose various modes for different modalities, such as mammography and breast MRI, ultrasound, and pathology, without the need to calibrate each time.
Using the bundled RadiCS LE software, modes can be set to automatically switch to optimal image viewing conditions with the click of a mouse or using the monitor's display mode.

Conserve Energy While Away
A presence sensor prompts the monitor to switch to power save mode when the user is away and resumes operation upon their return to conserve power when not in use. In the latest RadiForce models, the sensor detects the user's presence using a heat sensing method. This increases the range and angle of detection compared to conventional detection methods, making it effective when using multiple monitors.

Improve Operability
EIZO's highly versatile stand offers tilt, swivel, and a wide height adjustment range, enabling you to use the monitor with greater comfort.

Stay Confident with Stable Brightness
EIZO's confidence in its product quality extends to brightness stability which is also covered during the usage time specified in the warranty.

Mammography QC Standards Compliance
EIZO's easy-to-use RadiCS UX2 quality control software & calibration sensor (sold separately) performs precise calibration conforming to DICOM Part 14 and enables quality control (QC) complying with ACR Practice Guideline and other QC standard for digital mammography monitors.

Rest Assured with Medical Qualifications
The monitors meet the strictest medical, safety, and EMC emission standards.

Warranty with Safety and Trust
EIZO and its authorized distributors offer a five-year limited warranty.

Specifications:

Model Variations RX560-MD: Anti-Glare coating, two screens, dual stand
RX560-AR-MD: Anti-Reflection coating, two screens, dual stand
RX560: Anti-Glare coating, one screen
RX560-AR: Anti-Reflection coating, one screen
Cabinet Color Black
Panel  
Type Color (IPS)
Backlight LED
Size 54.1 cm / 21.3"
Native Resolution 2048 x 2560 (4:5 aspect ratio)
Viewable Image Size (H x V) 337.9 x 422.4 mm
Pixel Pitch 0.165 x 0.165 mm
Display Colors 10-bit colors (DisplayPort): 1.07 billion (maximum) colors
8-bit colors: 16.77 million from a palette of 543 billion colors
Viewing Angles (H / V, typical) 178° / 178°
Brightness (typical) 1100 cd/m2
Recommended Brightness for Calibration 500 cd/m2
Contrast Ratio (typical) 1500:1
Response Time (typical) 12 ms (on / off)
Video Signals  
Input Terminals DisplayPort, DVI-D (dual link)
Output Terminals DisplayPort (daisy chain)
Digital Scanning Frequency (H / V) 31 - 135 kHz / 23 - 61 Hz
USB  
Upstream USB 2.0: Type-B
Downstream USB 2.0: Type-A x 2
Power  
Power Requirements AC 100 - 240 V: 50 / 60 Hz
Maximum Power Consumption 87 W
Typical Power Consumption 43 W
Power Save Mode 1 W or less
Sensor Backlight Sensor, Integrated Front Sensor, Presence Sensor, Ambient Light Sensor
Features & Functions  
Brightness Stabilization Yes
Digital Uniformity Equalizer Yes
Hybrid Gamma PXL Yes
Preset Modes CAL Switch
OSD Languages English, German, French, Italian, Japanese, Simplified Chinese, Spanish, Swedish, Traditional Chinese
Physical Specifications  
Net Weight RX560-MD, RX560-AR-MD:
17.3 kg

RX560, RX560-AR:
8.1 kg
Net Weight (Without Stand) 5.3 kg
Hole Spacing (VESA Standard) 100 x 100 mm
Certifications & Standards RX560, RX560-AR:
CE (Medical Device Directive), EN60601-1, ANSI/AAMI ES60601-1, CSA C22.2 No. 601-1, IEC60601-1, VCCI-B, FCC-B, CAN ICES-3 (B), RCM, RoHS, China RoHS, WEEE, CCC, EAC
FDA 510(k) Clearance for Breast Tomosynthesis, Mammography, and General Radiography
Dedicated Software  
Monitor Quality Control Software RadiCS Supported
Supplied Accessories  
Signal Cables RX560-MD, RX560-AR-MD:
Dual Link DVI-D (3 m) x 2, DisplayPort (3 m) x 2, DisplayPort (1 m)

RX560, RX560-AR:
Dual Link DVI-D (3 m), DisplayPort (3 m)
Others RX560-MD, RX560-AR-MD:
AC power cords (3 m) x 2, USB cables (3 m) x 2, Utility Disk (RadiCS LE, PDF installation manual), instructions for use

RX560, RX560-AR:
AC power cord (3 m), USB cable (3 m), Utility Disk (RadiCS LE, PDF installation manual), instructions for use
Warranty Five Years

Please note that although care has been taken in the degree of relevancy, pictures are for display purposes only, and product appearance may differ from what you see. If there are any discrepancies between the product headline, description and picture, the correct information will be in the product headline (i.e. computer systems may not come with monitors even if pictured that way). If anything is unclear, please email support before placing your order.